Home > Labview Error > Labview Generic File I O Error Could Not Be Loaded

Labview Generic File I O Error Could Not Be Loaded

Contents

You know more about your software than anyone here does, so you need to tell us as much as possible about it in order to allow us to help you!   When deleting a directory, either first delete its contents and subfolders, or wire a True constant to the entire hierarchy input of the Delete function. Please tell us why. We still only can guess that it is probably the GPIB function causing that error. 1 person likes this Share this post Link to post Share on other sites Jordan Kuehn have a peek here

My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation. I handle a big amount of data coming from RT FIFO shared Var. Some information about the measuring system:There are three NI 9172 chassis which include the following modules:Chassis 1: 4x NI 9205; 1x NI9403; 1x NI9481Chassis 2: 8x NI 9217Chassis 3: 4x NI Related Links: AE KB 52BF05ZY: Why Do I Receive Error Code 6 When Building an Executable? http://digital.ni.com/public.nsf/allkb/2C99F5D635AE184C86256CD1005BBF65

Labview Generic File I O Error Could Not Be Loaded

Perform the following troubleshooting steps to resolve the error and successfully build your distribution: Use a shorter path, like c:\ Ensure that your file path is not pointing to an incorrect In this case it is not even software I wrote so how would we have been able to even guess from the first two posts of the OP that GPIB might If a file has been created recently in the programs execution, Anti-Virus software or some other software may have the file locked.

Share this post Link to post Share on other sites rolfk 360 LabVIEW Aficionado Members 360 2,595 posts Location:Netherlands Version:LabVIEW 2011 Since:1992 Posted July 9, 2015 My apologies.  Replace it This seems to have nothing to do with OpenG functionality at all, so should have been posted in one of the more general forums. 1 person likes this Share this post All guess work if you don't provide a LOT MORE information about your program, hardware and source code.   You usually don't go to a car shop and tell the mechanic Labview Error Codes Attached is a VI that demonstrates a solution that utilizes the Search and Replace Pattern.vi.This error could also occur if you specify a file name without a drive path inside a

an application (EXE), a shared library (DLL), source distribution (LLB), or web service). Labview Generic File I/o Error. ========================= Ni-488 I/o Operation Aborted This can be solved by creating a new folder to write to. Any help is greatly appreciated. have a peek here Actually, I have a "spinning" buffer with 150000*4 bytes of data, which is equivalent to 30s of measurement.

Please find attached my LabVIEW if required. You do not have read/write privileges to the path you are referencing. I would like to store them on the HDD of the controller, and try to use fastest I/O file operations by using Windows buffering disable. There must be many GB left.And after a restart of the system, everything works fine for another 2-3 weeks without deleting any data from the disk.

Labview Generic File I/o Error. ========================= Ni-488 I/o Operation Aborted

The Error number is  6. http://digital.ni.com/public.nsf/allkb/64F59210BE983DAA86256F1A00006160 Once this has been done, the source path that is input to Copy.vi only needs to contain the computer name and the shared folder name (i.e. Labview Generic File I O Error Could Not Be Loaded In Linux, you must open a pipe in Read Mode before trying to open it it Write Mode. Labview Error 6 Occurred At Delete Share this post Link to post Share on other sites Create an account or sign in to comment You need to be a member in order to leave a comment Create

The reason is that RT does not use buffering (probably the cause of error 6), and it must therefore read the old block before writing a partial block to disk. http://cygnussoft.com/labview-error/labview-error-1145.html The usage of the "Current VI Path" is also another one that does it. Solution: There are multiple reasons why you might be getting this error. Or sign in with one of these services Sign in with Facebook Sign in with Twitter Sign in with LinkedIn Sign Up All Content All Content This Topic This Forum Advanced Generic File I/o Error Labview

Please tell us why. All rights reserved. | Cart|Help KnowledgeBase Request Supportfrom an engineer NIHome > Support > KnowledgeBase EnglishJapaneseChinese(Taiwan) 8 ratings: 4.12 out of 5   Why Do So I really do not know how it functions but I know that it works because we ran it through different programs before and it worked perfectly. http://cygnussoft.com/labview-error/labview-error-1000-run-vi.html So maybe you login with a different user than before or your system administrator changed the access rights for your user account.   By the way: You posted in the wrong

All rights reserved. This works fine during some days, but it occured now twice (always after 2-3 weeks), that error 6 appeared and it poped up a message, that something with "Write Spreadsheet String.vi" Related Links: KnowledgeBase 2D5BNHDT: What Are Some Advanced Abilities of the LabVIEW Application Builder?External Link: MSDN: File Names, Paths, and Namespaces (Windows) KnowledgeBase 4ZNDQ2P4: Why Does Build Specifications Not Appear in

Why does this occur?

Make sure that the folder to which the file or directory is being copied has been setup to be a shared folder. My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation. Share this post Link to post Share on other sites chris754 8 Very Active Members 8 63 posts Version:LabVIEW 2013 Since:2006 Posted July 14, 2015 Sorry, For the late response You have NO error handling in that VI, which is BAD.

But i do not care as long as you provide me with information. See KB 4O08M6Z6 in the related links for more information. Our ion gauge displays the pressure that is connected to the computer through GPIB connection.   My Professor created a code that was made to read the pressure that is displayed this contact form Thank you for your help. 0 Kudos Message 6 of 6 (228 Views) Reply 0 Kudos All Forum Topics Previous Topic Next Topic Privacy | Terms of Use | Other Legal

Share this post Link to post Share on other sites Kyoma Hooin 0 LAVA groupie Members 0 5 posts Version:LabVIEW 7.1 Since:2014 Posted July 17, 2015 (edited) This is read A backslash, colon, or other control character is unintentionally included in the file path. Sign in here. All rights reserved. | Cart|Help KnowledgeBase Request Supportfrom an engineer NIHome > Support > KnowledgeBase English 4 rating: 1 out of 5   LabVIEW Error

Hi, If you want to stream data to disk as fast as possible, you must know the block size of the harddrive, and write data in chunks with size that is This seems to have nothing to do with OpenG functionality at all, so should have been posted in one of the more general forums.     As to where to post, The customer could then choose between "continue" and "stop". OK, they call them snippets, but they are screenshots and they say it is code, right?   You forgot a smiley there after the last sentence!  1 person likes this Share

Bill(Mid-Level minion.)My support system ensures that I don't look totally incompetent.Proud to say that I've progressed beyond knowing just enough to be dangerous. In my opinion, the disk can not be full. Showing results for  Search instead for  Did you mean:  Reply Topic Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the Top Bookmark The strangest part is that after the code stopped working on the newest program it stopped working on the old ones as well.   here is a picture of it   

The premise of the read is to read in the ENTIRE contents of the file just to get the last line. Please Contact NI for all product and support inquiries. It's easy! Or sign in with one of these services Sign in with Facebook Sign in with Twitter Sign in with LinkedIn Sign Up All Content All Content This Topic This Forum Advanced

Related Links: KnowledgeBase 3DMAD3CC: Why do I get an unknown error when building a PDA executable?KnowledgeBase 2UH9L2PK: Error 6: Generic File I/O Error when Disk is Full in LabVIEW Real-Time Attachments: What causes this to occur? Poor|Excellent Yes No Document Quality? Computer2\C:\SharedFolder), Error 6 will occur as shown above.

Ensure that any file paths or directories being accessed by LabVIEW do not exceed the maximum length for system file paths.