Home > Labview Error > Labview Error Code 50400

Labview Error Code 50400

With Best regards Hrachya

0 0 10/29/15--06:27: Labview Causes C# app crash with Code: 0xE0434352 Contact us about this article Hello everyone,   I have recently built a C# application Using Labview 8.6.1 April 2009 update on both PC and cRIO device. Pull Error (Native=28574, Internal Error, Error Code 80004005) 2 post • Page:1 of 1 All times are UTC Board index Spam Report INFO: Dieses Forum nutzt Cookies... Thanks,Asper 0 Kudos Message 1 of 4 (4,001 Views) Reply 0 Kudos Re: Error 50400 on FPGA to Host DMA FIFO Chuck_81 Active Participant ‎08-04-2008 02:23 AM Options Mark as New have a peek here

It also has a "watch" function in case VeriStand or TestStand crashes while executing.   The problem is that LabVIEW causes the application to crash with an error code 0xE0434352 while WSUSand error 0x80244019, soap error code = 0, HTTP status code = 3. 80048820 error code, extended error code 80048411 4. I am creating databases of some products but also need to print to PDF417barcode format some important features. Hi ALL, Now I am working on developing Drivers for SCANLAB RTC5.

I will do my best to help you. The other alternative I rejected was to just treat the K-type as a mili-volt signal but I suspect that isn’t a good idea. It would be very much appreciated if you can provide with some examples. kombiniert mit einem boolschen Flag, das neue Werte signalisiert?

Why does this happen and how do I fix it? What I suggest is to filter this error code -50400 by using a simple unbundle function for the error cluster wire and comparing the "code" value with -50400; then you can Then accessed the BioRobotics/Vicon palette.       4)We placed the Get Ref subVI on the block diagram, opened it up, and ran it it.   5) We got the following Nov 30 Is it true that the 32GB iPhone is capable of 17 straight hours of video Nov 30 Failure Text for Darg and Drop Oct 11 What happened to the

Cannot Install Itunes 8.0.1..."Ipod Service" Error. can you pleas help with the problem. I haven't seen any problems with the machine View All Replies From Thread On Windows Platform, encounters error when trying to open an Indesign document created from MAC Hi all, On their explanation In this case you could have. [Morewiththissubject...] Re: error code -50400, Bruce_Columbia Re: error code -50400, andre .

I have made sure the 'Automatically close VISA sessions' option is unchecked. However, if I launch labview by opening the library VIPM installed, all of the VIs will work, and LabVIEW is able to locate the the .Net framework and it appears in Any suggestions/comments are greatly appreciated.   Thanks, Bing

0 0 10/29/15--12:55: Creating drivers using an unsigned .NET framework and distributing through VIPM Contact us about this article Hi all,   I monitored the "Empty Elements Remaining" on "Host-to-FPGA.Write" in the host vi and the value was 5.

I hope that makes helping me a little easier. I cannot find a setup error code in the KB (error code is 4) 2. Showing results for  Search instead for  Did you mean:  Reply Topic Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the Top Bookmark I have set: Number of Elements: 1 Timeout (ms): 0 The Windows routine read recursively (every 100 ms) the FIFO to get the FPGA analysis results.Because of different conditions, the FPGA

when I send the signal to PFI0, I get 2 events as well!  Should not get any.  The VI is Not looking at PFI0.  Any ideas as to what I'm doing navigate here TCP Read or VISA Read, the read 'data' is always a string, but depending on what you are doing, often that string is more efficiently handled/interpreted if converted to a U8 Dankee 16.09.2013, 12:04 Beitrag #2 GerdW ______________ Beiträge: 13.875 Registriert seit: May 2009 09SP1, 11SP1, 14SP1, (16) 1995 DE_EN 10××× Deutschland RE: Fehler -50400 FIFO auslesen Hallo Mietze, Gegenfrage, warum error code is 80004005 and error code 1603 9.

Mit der Nutzung des Forums erklärst Du dich damit einverstanden, dass wir Cookies verwenden.Es wird in jedem Fall ein Cookie gesetzt um diesen Hinweis nicht mehr zu erhalten. I am a student who is pretty new to Labview FPGA and i ahve a big task to finish. The transfer did not complete within the timeout period or within the specified number of retries.What happened: The node didn't receive all of the 1000 elements within the timeout specified (50000 http://cygnussoft.com/labview-error/labview-error-code-9.html I am using the NI crio-9014 RT controller with the NI-9104 fpga backplane and the program is accessing a 9236 module and a 9237 module via FPGA programing (not scan mode

View All Replies From Thread Error:Adobe document services error: SOAP Runtime Exception: CSoapException Dear All, While executing an adobe form I am facing the following error: Adobe document services error: SOAP Themen Verfasser Antworten Views Letzter Beitrag unplausible Werte aus FIFO kwakz 2 1.186 28.09.2015 06:05 Letzter Beitrag: kwakz FPGA FIFO - Oszilloscop PxCE_HB 9 1.965 08.09.2015 14:35 Letzter Beitrag: natinst.public.daq.real-time.general Discussion: when RT controller programming runs gives -50400 error (too old to reply) Eicher Engineering Solutions 2008-05-01 07:40:15 UTC PermalinkRaw Message hi,I am using cRIO-9104 with 9004 controller.I am using

LabVIEW basics - LabVIEW training - Students LabVIEW training - Learn NI THINK DATAFLOW - Race Condition DAQmx-Basics - FP numerics basics - FP numerics 2 16.09.2013, 12:55 Beitrag #3 Mietzekatze

I have two event cases in a while loop. My problem is I have to calibrate 6 k-type thermocouples between minus 76°F and plus 194°F.  6 off probes plus the reference inserted into a ali block this is placed in Contact us about this article Chipping away at this project.  I've got the task running and finally all my scaling correct and plotting a continuous trace to the waveform graph from the Error installing updates Exit code=0x80240FFF;Call error code= 8.

Whenever I have my iPod plugged in to the computer and open iTunes, I get the "please rein View All Replies From Thread No rfc destination defined for global trade services Windows Update Error Code 80070422 and Error code 1058 6. I am getting the same error code after some time. http://cygnussoft.com/labview-error/labview-error-code.html Details: Error -50400 occurred at Project Window.lvlibroject Window.vi >> Project Window.lvlib View All Replies From Thread RTC-5301 - Runtime Platform Service not running Hi, I am using Oracle 10.

techbreak 2008-05-06 13:40:13 UTC PermalinkRaw Message hi specialist,               actually i am using first time this forum support thats why i m not much familiar about its procedure,now its ok.:smileyhappy:I am sending I have implemented datalogging in many previous applications, but this one is tricky.   I need to log data of few seconds before and few seconds after the alarm trigger has At each temperature 7 readings are taken and so on. Cannot Install Itunes 8.0.1..."Ipod Service" Error.

Nun bekomme ich ab und an nach unterschiedlicher Zeit (2-10 min) den Fehler -50400 Error -50400 occurred at Invoke Method: FIFO.Read :NI Platform Services: The transfer did not complete within the i am attaching the Vi.

0 0 10/29/15--08:07: Are "String to Byte Array" and its twin "Byte Array to String" in-place (memory) operations? (or do they incur copy/memory operation penalty?) Showing results for  Search instead for  Did you mean:  Reply Topic Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the Top Bookmark I have recompiled the fpga file many times, with no errors or problems.

My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation. yes no add cancel older | 1 | .... | 594 | 595 | 596 | (Page 597) | 598 | 599 | 600 | .... | 874 | newer HOME The error I View All Replies From Thread Platform Service not running - Windows 7 Ultimate 32bit Network Magic v5.5.9195.0 tells me that the platform service is not running - however Make time out larger;2.

Please tell us why. I am trying to read 10 channel data at a time and i am using 10 different fifos for it. auch nach dem Timeout (5s) ist sehr suspekt für mich^^. Vielen Dank! 16.09.2013, 11:20 Beitrag #1 Mietzekatze LVF-Gelegenheitsschreiber Beiträge: 118 Registriert seit: Nov 2011 2014 SP1 2011 DE Deutschland Fehler -50400 FIFO auslesen Hallo ich betreibe mein cRIO im FPGA Modus.

Ask the number of available elements before reading the elements.Hope this will be of help.A lot of the time the solution can be derived from the error description, sometimes it can't. Please Contact NI for all product and support inquiries. One thing needed to be implemented is logging of data when alarm condition occurs. Error code when downloading updates Error Code: 0x80240017 5.

techbreak 2008-05-06 07:10:10 UTC PermalinkRaw Message hi specialist,                       I have used fpga fifo size smaller than RT fifo size.Still i m not able to achieve data greater than 25Khz.I have set