Home > Labview Error > Labview Error Code -1073807339

Labview Error Code -1073807339

Contents

The sound format of this file is not recognizable. Recompiling the VI may fix this issue. 4800 Selected Device is Invalid The currently selected device index is invalid. Fix the errors before attempting this operation. 1499 Library has edits in another context. This error occurs when you try to use the Active Frame property with a Conditional Disable structure. have a peek here

The file may be corrupt. 4811 Cannot support sound format. In this mode, a carriage return is \r, a line feed is \n, and an end of line is \r\n. There is already a VI in this hierarchy with this name. 1449 Arrays must have at least one dimension and a maximum of 63 dimensions. 1450 One or more untitled library Additionally, can verify that you are not trying to read too many bytes by reading only 1 byte at a time. https://zone.ni.com/reference/en-XX/help/371361J-01/lverror/visa_error_codes/

Labview Error Code -1073807339

We are using also PIC's and never had a problem to make any communication to LABView. 1 Kudo Message 2 of 19 (30,325 Views) Reply 1 Kudo Re: ERROR->1073807339 occured at After the reference is opened, that VI can return the reference to other VIs that could not normally open the reference. 1396 Cannot convert text from the source character set to Unable to checkout the requested license feature because the license is invalid or does not exist. 1381 Cannot create semaphores with a size less than one. 1384 Cannot start dragging because You mentionned that you are using the example.

You can use the Conditions property and the Get Frame Index method only with the Conditional Disable structure. 1378 Cannot set the Active Frame property on a Conditional Disable structure. You must call the class driver Initialize VI before you can call a specific driver VI. If you do not have the right amount of data to align to a sector size, you must pad the data with filler data and delete the filler data before LabVIEW Labview Visa Read Error If it is reentrant, use the Open VI Reference function with the options input set to 0x08 to prepare the VI for reentrant run or use the Open VI Reference function

This is usually due to a required driver not being installed on the system. You cannot add library items to folders that do not belong to the library. 1483 Cannot change width of the plot legend when you configure the plot legend to automatically resize, The file serpdrv is not available (only for LabVIEW 6.1 and earlier Serial Compatibility VIs). A timing source such as IEEE-1588 or GPS modified the global time value on the controller.

This error also can occur if you used a model that is not officially supported by this driver. Error -1073807339 Occurred At Visa Read To correct this error, verify that the file is not in use by another application and that file permissions are set correctly. This mismatch implies that the dependency report is unreliable, so the ReadLinkInfo operation was aborted. 1595 The RT target does not have enough memory to load the startup application. 1596 Cannot This error can occur if you attempt to edit a VI that is running or reserved for running.

Labview Error 1073807339

My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation. If you are running an executable built in LabVIEW and LabVIEW is open, LabVIEW may already have control of the serial port. Labview Error Code -1073807339 An input task might stop running if the input buffer overflows. Ni Error Set Segment Headers to One header per segment to correct this error. 1 An input parameter is invalid.

VI_ERROR_NSUP_ALIGN_OFFSET BFFF0070h The specified offset is not properly aligned for the access width of the operation. navigate here VI_ERROR_INTR_PENDING BFFF0068h An interrupt is still pending from a previous call. If you are using the Open/Create/Replace File function or Open/Create/Replace Datalog function, you can wire cancelled to the selector terminal of the case structure instead. Right-click the container border and select Replace or drag new subtype. 1096 The Open VI Reference function cannot prepare a non-reentrant VI for reentrant run. Labview Error Handling

VI_ERROR_INV_PARAMETER BFFF0078h The value of some parameter--which parameter is not known--is invalid. This item has been edited in another context on this machine. Add Comments 1 2 3 4 5 My Profile|Privacy|Legal|Contact NI© National Instruments Corporation. http://cygnussoft.com/labview-error/labview-error-code-9.html VI_ERROR_IN_PROGRESS BFFF0039h Unable to queue the asynchronous operation because there is already an operation in progress.

but nothig seems to wrktillnow please help as im getting stuck thanks 1 Kudo Message 3 of 19 (30,321 Views) Reply 1 Kudo Re: ERROR->1073807339 occured at VISA read in Labview->Serial.vi Visa Read Byte Count Save any work to a new location and restart LabVIEW. Poor|Excellent Yes No Document Quality?

To set the state of the open front panel, use the Front Panel Window:State property. 1151 Invalid input for front panel state. 1156 Memory full error, possibly due to a data

zainudin visa serial not working.JPG ‏96 KB 0 Kudos Message 7 of 19 (28,661 Views) Reply 0 Kudos Re: ERROR->1073807339 occured at VISA read in Labview->Serial.vi Dennis_Knutson Knight of NI ‎05-14-2008 VI_ERROR_RSRC_BUSY BFFF0072h The resource is valid, but VISA cannot currently access it. This error code is not currently reported by the LVSound library. 4805 Could not find the sound file. Visa Declined Codes For example, this error might occur when a front panel terminal is inside a structure. 1430 The path is empty or relative.

Parsing error. An error occurred converting from LabVIEW type to OLE variant type. 88 Run-time menu error. 89 Another user tampered with the VI password. 90 Variant attribute not found. 91 The data Unnamed mechanisms do not have this restriction, because each request to obtain an unnamed mechanism creates a new mechanism. 1095 This container cannot be left without a subtype. http://cygnussoft.com/labview-error/labview-error-code.html Refer to the KnowledgeBase for more information about correcting errors in LabVIEW.

On Linux or Mac OS X use chmod to set file permissions. To correct this error, remove either the 0x08 option or the 0x80 and 0x100 options. 1604 The Open VI Reference function does not support using the option 0x08 (Prepare for reentrant VI_ERROR_ASRL_PARITY BFFF006Ah A parity error occurred during transfer. Poor|Excellent Yes No Document Quality?

thanks once again rohit Serial_general.vi ‏55 KB 1 Kudo Message 6 of 19 (30,308 Views) Reply 1 Kudo Re: ERROR->1073807339 occured at VISA read in Labview->Serial.vi Zainu Member ‎05-14-2008 11:33 PM The sound driver or card cannot accommodate the specified configuration. For example, the network connection is down or a network cable is unplugged. 8 File permission error. Attempted to read from or write to a file of a type incompatible with the operation.

The values were clipped to fit within this range. −4820 A buffer underflow has occurred. I'm attatching the code written in MPLAB IDE for PIC and the serial.vi i'm using present in the installaiton examplesfor the same. Note: These solutions also help resolve Error 37: Device Not Found that occurs when using Serial Compatibility VIs. However, I do not see how the data / info is sent to the serial buffer.

If this error occurs, you must enable buffering and reopen the file. 1546 The VI must be in a project to use this property. 1548 Queue refnum cannot be obtained with Select File»Open to open the VI and then verify that you are able to run it. 1004 The VI is not in memory. 1005 VI execution has been disabled in the Verify that NI License Manager is installed on the computer by selecting Start»All Programs»National Instruments»NI License Manager. 1322 Invalid project build reference. 1357 A LabVIEW file from that path already exists The file might have been moved or deleted, or the file path might be incorrectly formatted for the operating system.