Home > Labview Error > Labview Error 1055

Labview Error 1055

Refer to the National Instruments Web site to download the VIs. 1196 Cannot list the same terminal more than once in the grown region of the expandable subVI. 1197 This operation This error code is not currently reported by the LVSound library. 4805 Could not find the sound file. I am now in the process of removing them both and starting the DVD install program from scratch..... On Windows, navigate to the file, right-click the file, select Properties, and set the Read-only option in the dialog box. have a peek here

A filename is no longer sufficient because the full name of a VI now includes any owning libraries. The palette view format must be Icons, Icons and Text, or Text. So you might think that the issue was just some obscure configuration item, or I'd used the wrong type in my reference or something. A specified refnum was not valid. −1967345151 Invalid property code. hop over to this website

You cannot add an ability multiple times. 1470 Specified folder is outside the library. If you do not have the right amount of data to align to a sector size, you must pad the data with filler data and delete the filler data before LabVIEW A VI item in the palette data array is not supported in this version of LabVIEW.

The important portion of his message was to install the update OVER the DVD version of LV. One of the common issues we've seen is to install the update over the trial version or other version of LV without having all of the appropriate toolkits installed. If you obtain a queue reference in one application instance, you cannot use that queue reference in another application instance. I ended up deleting all versions of LabVIEW and reinstalling from the DVD followed by the update.

This error occurs when you use an index value that is out of range to access a frame in a Case, Stacked Sequence, or Event structure. 1313 You cannot use this In a built application, this error might occur because the VI being loaded was last compiled for a different OS, in which case you must save the VI on the current When a Boolean control is configured with a latching mechanical action, the Value property always returns an error. Open the Execution Property Page of the VI Properties dialog box to change the settings for the VI execution. 1006 FPDCO on connector pane thinks it is constant. 1007 No IP

The return type must be Void, Numeric, or String. To correct this error, load an instance of the polymorphic VI rather than the polymorphic VI itself. 1554 The current LabVIEW target cannot load control VIs. 1556 The reference is invalid. To correct this error, verify that the file is not in use by another application and that file permissions are set correctly. Unnamed mechanisms do not have this restriction, because each request to obtain an unnamed mechanism creates a new mechanism. 1095 This container cannot be left without a subtype.

A bad format specifier was found in the Format String input to a Format Into String or Scan From String function. 83 Too few format specifiers. Make sure you include the front panel of the VI when building a stand-alone application. 1014 Linker error. 1015 Printer is not responding. Code Description −2147467259 Unspecified error. −1967345152 Invalid refnum. A format specifier does not match the data type of its corresponding argument in a Format Into String or Scan From String function. 82 Unknown format specifier.

Ensure that the parameters values are within the supported range for the hardware and drivers. −4406 A VI item in the palette data array is not supported in this version of http://cygnussoft.com/labview-error/labview-error-88705.html You need to install the update over the LabVIEW version included in the kit. You cannot use user events for communication between LabVIEW application instances. is FALSE and a queue or notifier with that name was not found, LabVIEW returns this error. 1102 The string wired to the xml string input is empty. 1103 The XML

There is already a VI in this hierarchy with this name. 1449 Arrays must have at least one dimension and a maximum of 63 dimensions. 1450 One or more untitled library Further the cluster pipe through the event structures has been finxed and now it is running smoothly! To correct this error, wire the required input. 1398 The subVI cannot be inlined because there is a local variable in the block diagram. 1399 The subVI cannot be inlined because Check This Out Quote: Originally Posted by Vince Thanks Joe - I had installed the update when I got the error message.

Who knows. Verify the path for each item in the items array. on May 3, 2015.

In my tests, this issue seems specific to Context Help.

Verify the ability name does not contain spaces. 1469 Specified ability already exists. These two are very similar, but not identical. I don't know why but somehow the terminal type of the cluster was wrong when it was auto-updatig from the type def. This error can occur if you attempt to edit a VI that is running or reserved for running.

The palette type input is invalid. A possible cause for this error is the disk or hard drive to which you are trying to save might be full. I found the display reference in the parent VI was not even wired to the sub VI - duh! http://cygnussoft.com/labview-error/labview-error-50202.html Any other suggestions?

Most likely the VI is broken or one of its subVIs cannot be located. Verify that NI License Manager is installed on the computer by selecting Start»All Programs»National Instruments»NI License Manager. 1322 Invalid project build reference. 1357 A LabVIEW file from that path already exists This typically results from recursion without a proper termination condition to stop the recursion. 1532 The target application instance is currently being destroyed. on May 6, 2015.

One of the common issues we've seen is to install the update over the trial version or other version of LV without having all of the appropriate toolkits installed. All rights reserved. Cart|Help KnowledgeBase Request Supportfrom an engineer NIHome > Support > KnowledgeBase English 5 ratings: 2.60 out of 5   Error 1055 When My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation. Showing results for  Search instead for  Did you mean:  Reply Topic Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the Top Bookmark

All rights reserved. | Cart|Help You are here:NI Home > Support > Manuals > LabVIEW 2010 Help General LabVIEW Error Codes »Table of Contents LabVIEW 2010 Help Edition Date: Only that instance can be reverted. 1468 Specified ability not supported by the library.