Home > Labview Error > Labview Error 1000 Run Vi

Labview Error 1000 Run Vi

There is still usually a "Run VI" up at the top that launches it, but the code itself is more of a queued state machine. Poor|Excellent Yes No Document Quality? If the foreground code calls it with a "shutdown" action, the action engine can verify successful shutdown before returning. Let me ask the testers to test it...... have a peek here

Does anyone have an idea of what is going on? The execution of a VI depends on the execution of the subVI that is called, so you are not allowed to abort the execution of a subVI. It will still call the correct dynamic dispatch VI. No one should ever see that error unless they do not understand LabVIEW!

Administrators 274 5,736 posts Version:LabVIEW 2015 Since:1994 Posted March 3, 2006 Hey all, I'm using VI server to load and run a VI dynamically, but I'm getting: Error 1000 occurred at Shane. My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation. So...

When I run the MainVI using "Run when Opened", I get a Error 1000 and the SubVI freezes. but I didn't get the errors you mentioned. Error 1003 : LabVIEW VI is not Executable This error can occur when the VI cannot locate its subVI's in the the location they were when the VI was developed. See the examples in 2014 0 Kudos Message 5 of 8 (469 Views) Reply 0 Kudos Re: Error 1000 kabooom Member ‎01-15-2015 01:25 AM Options Mark as New Bookmark Subscribe Subscribe

Make sure to set Auto Dispose Refnum to TRUE, so that the lifetime of the wrapper is decoupled from the VI that spawns it. Error 7: LabVIEW File not found This error can occur when the specified file path is not correct. it works and I'm too pessimistic about this Share this post Link to post Share on other sites shoneill 79 The 500 club Members 79 715 posts Posted October 17, click to read more Then use VI Server to call that subVI.

Powered by Blogger. The major drawback to this however, is the greater difficulty of passing data values to the called VI. Sign In Sign In Remember me Not recommended on shared computers Sign in anonymously Sign In Forgot your password? Share this post Link to post Share on other sites Kevin P 1 Very Active Members 1 63 posts Posted February 20, 2008 I used to use the "Run VI"

Error 66: The network connection was closed by the peer The network connection might have been closed by someone, or LabVIEW is not configured to allow you to be a client. https://lavag.org/topic/2986-calling-a-vi-using-vi-server-the-vi-is-not-in-a-state-compatible-with-this-operation/ In the second case, you must configure the VI Server to give you the appropriate permissions by selecting Tools»Options (or Edit»Preferences in LabVIEW 5.x). I dont have to do any operation with the H/W....Its absolutly fine...I just need to a way to perform a self kill. template.

is this just a way of checking whether your remote hardware is on the network. navigate here Don't know if that's related to the error at hand, but in the end it didn't surprise me. This works properly in labview 2010 SP1, XNET 1.1.1 and with the same code in labview 2014 XNET 14.0 we get the error 1000 when we want to abort the vi Can someone analise the same and let me know whats happening in this vi.PS: The reason why i am killing it because the "System Exec" hangs or enters to "dead lock"

Sometimes background code needs to be halted gracefully, but immediately. If you are enforcing a strict con-pane adherance of plug-ins, then this might be the best approach. And this is as far as I've gotten...I keep coming back to the same problem of being unable to define which method is going to be called at design time, yet http://cygnussoft.com/labview-error/labview-error-88705.html Or sign in with one of these services Sign in with Facebook Sign in with Twitter Sign in with LinkedIn Sign Up All Content All Content This Topic This Forum Advanced

Share this post Link to post Share on other sites shoneill 79 The 500 club Members 79 715 posts Posted October 17, 2008 QUOTE (normandinf @ Oct 16 2008, 05:20 I'm sure AQ will step in to give the exact reason why it doesn't (or maybe shouldn't ever) work. The Make Current Values Default method is an example of an editing method.

Don't know if that's related to the error at hand, but in the end it didn't surprise me.

Otherwise, this method is similar to pressing the Abort Execution button on the toolbar. Double-check the path you entered. Debugging Techniques - LabVIEW 2011 Help - Nationa... The VIs should stay open after the call running independently of each other and the caller should not be waiting until the VI stops.

I'd start dropping error > indicators or probes after any property nodes and run it on > the PDS system that's failing to see where the error is > originating from. Generally the "abort VI" is not elegent since if the VI you are aborting is waiting on an I/O, the resource associated with that I/O must be cleaned-up. Internally, it has its own rules for state transitions, but it can additionally be sent action messages asynchronously from the foreground code. http://cygnussoft.com/labview-error/labview-error-out-cluster.html Both "A" & "B" work without problems when the VIs are running under the LabVIEW development system. "A" can also start "B" without problems running under the development system.

Solution: Even though the subVI that you called is running, it is not running under its own execution; it is part of the execution of the top-level VI.