Check wiring fuses and LEDs are lit. liamsi on June 14, 2016 at 10:43 AM said... Have now confirmed that the fault is with the exterior PCB. I'm not in a position to throw good money after bad .... navigate here

Check pressures, check for non condensables, check heat exchanger coil is free from debris 155 Sub 3 reverse or open phase. Check solenoid coil and output from PCB. is recovred) 2. My unit keeps turning off after displaying an * and drop symbol!

Lg Air Conditioner C5 Error

Switching off at the Fuse Box clears the error.Steps taken after that.1. Check motor for mechanical and electrical failure. Check system pressures for non-condesables 62 Inverter over 85C. Contributor 4 Answers Re: ERROR CODE ON AIRCONDITIONER LG ART COOL INVERTER...

I have tried to get assistance on the LG service site, but nothing on error codes. Multi V = Indoor unit EEPROM error - Replace the indoor unit PCB, and then make sure to do Auto addressing and input the address of central control. 9 Split Check to earth 50 MOhm minimum, check run current CH23 Inverter dc voltage low. Lg Neo Plasma Error Codes Any other constructive comments welcomed - Hmmmm, I think!

We bought them because they looked nice. There is a lot of soldered joints on the board that appear corroded/dull/dry. http://www.retrevo.com/support/LG-LA121CNP-Air-Conditioners-manual/id/438ci272/t/2/ This "Clicking" is usually a Power Supply failure, I would imagine that when testing you may have been, "Spiked", and this has caused the power Supply to fail, or perhaps Pull it up swap over and you are good to go again, Worked on both my units that had this fault.

it stopes the unit and after i reset working for 5 min.and stops again. Lg Air Conditioner Troubleshooting Problems Pipe Sensor (Open/Short)LED01G = 4 times(Red) LED02G = 5 times(Green)Case Of Error = Open / Short circuit.Outdoor Status = OffError Code = 46Contents = Suction Pipe Sensor (Open/Short)LED01G = 4 times(Red) c6 on the art cool unit bought in 05 and this is the first time. please do NOT try this i could damage your unit if you don't know what you are doing call a service provider.

Lg Air Conditioner Error Codes Pdf

C6 Error on LSZ2144VM4 ArtCool Installed October 25th 2005, first error. Should be good enough for testing unless something has gone wrong between the diode bridge and IPM. Lg Air Conditioner C5 Error Check model number of units do not exceed maximum. Lg Mini Split Error Codes Posted on Jun 23, 2008 Helpful 4 Not Helpful 1 Comment Flag Hamish Browne Jan 13, 2011 After a C6 fault in our ArtCool A/C the tech replaced the Capacitor which

Check wiring fuses and LEDs . check over here If there is no voltage, the outdoor PCB is faulty 4.   If the tests in 2 and 3 above show the correct voltage, the fault lies in the interconnecting cable. my lg model is lsz244vm-4, it's run well now. help Text the 1, 2 or 3 digit fault code number only. Lg Air Conditioner Error Code Ch 05

Forecast of 32C +! I presented my HVAC tech with a name, picture and description of what I wanted, I paid for it, and when it arrived I paid my tech to install it. If OK change outdoor inverter PCB 29 no such fault code Text 1, 2 or 3 digit fault code number only. his comment is here You may have to register before you can post: click the register link above to proceed.

Yet another invoice....I feel that the companies involved are going to dilly-dally until my one year warranty is up. Lg Air Conditioner Ch 10 Error Website Developed by Neerja Softwares Pvt. is recovred) C18AW*  C24AW*  LG ART COOL error codes 1.

check fuses, if fuses OK replace outdoor main PCB 173 Main outdoor unit standard compressor not starting.

Check dc voltage between white and black cable on plug. Called to unit which according to client is 'short of gas'. take about less than 10min to install. Lg Art Cool C5 Error Slim air conditioner error codesPanasonic air conditioner error codesPanasonic cassette air conditioner error codesSamsung air conditioners error codesSamsung free joint multi air conditioner error codesSanyo Wall Mounted Air conditioner error codesSharp

The other unit has just thrown the code and is being looked at tomorrow morning so i will list what was replaced... Low at 1 bar High at 35 bar check pressures. In 30 mins, weighed in exact charge. http://cygnussoft.com/error-code/lg-air-conditioner-error-code-ch-05.html Please try the request again.

Oct 19, 2016 | Air Conditioners 0 Answers Basic airconditioning cl error apearred when the unit turning off how do i reset Oct 19, 2016 | Air Conditioners 0 Answers I The readings of maximum Voltage should be the same for all 3 measurements if not the PCB is faulty it will need replacing, if they are all equal the compressor is When we turn it off at the mains it seems to reboot it for a while... Graham en boca cerrada no entran moscas 11-08-2013,08:06 PM #12 install monkey View Profile View Forum Posts View Blog Entries View Articles VIP Poster I am starting to push the Mods:

Not too sure where to get LG parts here - could be interesting!! I Have just purchased this ART COOL in december, and I have the error msg "C5" Same problem you guys are having, nothing working. Set to Sg for 1 unit, or Gr for group then reset power 04 RAC Product = Heat Sink Sensor Error, Open/Short Cct or over 95C. Slim P Series A air conditioner fault codesMitsubishi MR.

Look for the inverter module on the PCB. Jan 11, 2011 | LG LSC183VMA Split System Air Conditioner 2 Answers My Art cool was working fine. Jun 01, 2009 | LG Art Cool LA091HNP Split System Air... 2 Answers C4 error code on LG artcool airconditioner www.yx2.fi/LG/wall_and_art_cool_error_codes_2007.pdf Please read this article, I think it will help you Need help...

Check pressures, and check service valves open CH36 no such fault code Text 1, 2 or 3 digit fault code number only.