Home > Error Code > Labview Fpga Error Codes

Labview Fpga Error Codes

Contents

My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation. Regards, . If you're using wired Ethernet, that means turn off the wireless (we also had a FireWire network connection showing that had to be disabled). __________________    :: qo'mey poSmoH In your case you can only have one instance of the VI running (because it is non-reentrant) so I don't think it matters here (but I'm not sure?!). have a peek here

I re-installed the NI-RIO driver and problem is still present. See the MAX Help for instructions on upgrading CompactRIO software: Open Measurement & Automation Explorer. But I will do the user event method, it sound more sophisticated Yes, User Events are awesome for this situation.  I actually do not pass them in.  I have the User NI-RIO server is running on the laptops with firewall disabled (I tried a static port first).

Labview Fpga Error Codes

Greg, Thanks for the reply. However, when I do this, the program shortly fails because the acceleration reaches infinity. The Chief Delphi Forums are sponsored by Innovation First International, Inc. -- English (12 hour) -- English (24 hour) Contact Us - Chief Delphi - Rules - Archive - Top Powered I've never been able to get a connection to the cRIO to debug our code once it's been deployed as a start-up application.

Contact us about this article Hi all, I'm trying to simulate the trajectory of a particle in a 2D box. From: muks Re: How should i solve this error code 63040 ? All rights reserved. I've never been able to get a connection to the cRIO to debug our code once it's been deployed as a start-up application.

From: roxylat Prev by Date: Re: how to build a installer from the executable code of a labview program in Linux? Labview Fpga Error "-61017" All rights reserved. Cart|Help KnowledgeBase Request Supportfrom an engineer NIHome > Support > KnowledgeBase EnglishKoreanChinese(China)SpanishChinese(Taiwan) 15 rating: 1.93 out of 5   Error -63040 When Do They Have FIRST Teams? https://forums.ni.com/t5/LabVIEW/Error-Code-63040-in-LabVIEW-FPGA/td-p/2309180 Greg McKaskle Greg McKaskle View Public Profile Find all posts by Greg McKaskle Find CD-Media Photos by Greg McKaskle Find CD-Media Papers by Greg McKaskle #3 04-29-2010, 08:57

They are better described as remote access points to a front panel control or indicator terminal. Why can't the error description say "verify IP settings." This solved my issue. 0 Kudos Message 3 of 3 (623 Views) Reply 0 Kudos All Forum Topics Previous Topic Next Topic Unfortunately, there was a typo on the error code, it should be -63040, not -60040. Your program should be constructed so that everything which needs to repeat is inside a loop.

Labview Fpga Error "-61017"

yes no add cancel older | 1 | .... | 367 | 368 | 369 | (Page 370) | 371 | 372 | 373 | .... | 922 | newer HOME imp source I cant use my cRio. Labview Fpga Error Codes I have read all I could find on this error, and tried all the suggested fixes - both from NI's site and the MAX help; and yet it persists. So it maybe that the fpga is not started, but why?

0 0 02/17/15--07:24: Re: pop up dialog async call and forget Contact us about this article Hello,   "I

Ensure the device is on an accessible over the network, that NI-RIO software is installed, and that the RIO server running and properly configured." Before I setup the network the everything navigate here From: mickeyw Date: Fri, 8 Aug 2008 04:40:12 -0500 (CDT) Hi Roxy, Below are a couple of resources that explain the error you are receiving and how to correct them.

Can you connect to the cRIO within Measurement and Automation Explorer? Related Links: KnowledgeBase 429H47J8: Why Does My Networked Device Not Show Up In Measurement & Automation Explorer (MAX)? The part I'm struggling with is adding drag force and central force terms to the code.   I want to add a drag force term that is proportional to the square Check This Out You could create a byte stream sequence that contains UTF-8 encoded characters but when you convert/cast it into a LabVIEW string LabVIEW will interpret it as a string in the current

Answered Your Question? 1 2 3 4 5 Document needs work? Find all posts by Alan Anderson Find CD-Media Photos by Alan Anderson Find CD-Media Papers by Alan Anderson #5 04-29-2010, 11:15 PM davidc10 Registered User FRC #0423 I managed to make it work randomly before, but not now.

I'm not sure where the error is showing up.

For FRC, we essentially ignore the existance of MAX... First, make sure that your CompactRIO target can be discovered in NI MAX. If this is by design also, (NI FRC support couldn't tell me at the time), it would be helpful to have documentation about it so as not to waste time trying Quote: Originally Posted by davidc10 Another example is Debugging a Stand-Alone Real-Time Application.

Another example is Debugging a Stand-Alone Real-Time Application. Answered Your Question? 1 2 3 4 5 Document needs work? Ensure that it matches the IP address of the sbRIO in MAX and try again. this contact form I could maybe check if the dialog is open via an invoke node?

LabVIEW have features that can help you. However, I am still able to perform a pingto the controller indicating it is accessible over the network.Why do I receive this error even when the device is accessible over the Poor|Excellent Yes No Document Quality? Quote: Originally Posted by davidc10 Have you been able to get the Web Server up on the cRIO?

you should too. I do not understand very well if you want to change your Python program to a LabVIEW program that uses Web Services or if you are looking into hardware that can Press F1 to open the MAX Help. I suspect it is something in yourcode.

If this dialog is open when the user closes the top level MAIN VI, how should I check it and close the pop-up VI? For NI-RIO 2.3 and later, refer to Software>>NI-RIO>>NI-RIO Settings under the system in MAX.Prior to NI-RIO 2.3, refer to Software>>NI-VISA>>VISA Options under the system in MAX.   Sometimes it gets resolved